      current position:Home>Product Center

      Product Center

      • FL(R)N48 Indoor SF6 Gas Insulated Load Break Switch
      • FL(R)N48 Indoor SF6 Gas Insulated Load Break Switch
      • FL(R)N48 Indoor SF6 Gas Insulated Load Break Switch

      FL(R)N48 Indoor SF6 Gas Insulated Load Break Switch

      FL(R)N48 Indoor AC High Voltage SF6 Load Break Switch and LBS-Fuse Combination are used for the three-phase AC 50/60Hz RMU and terminal power station. The switches are suitable for protecting the 12kV power system's on load situation. The switch can switch off the on load current, closed loop current, no load transformer capacity and cable charging current. The switch with fuse combination can cut off any current, when the current is in the range of the rated short-circuit breaking current. They are suitable for the RMU, combined transformer, etc..

      Technical Information

      Technical Specification

       

       

      Rated voltage

      kV

      12

      Rated current

      A

      630

      Rated power frequency

      Hz

      50/60

      Short circuit making capacity

      kA Peak.

      62.5

      Peak withstand current

      kA Peak.

      62.5

      Short time current

      kA eff.

       

      1Sec.

       

      25

      Max. breaking capacity in co-operation with fuses IEC 62271-105(IEC 420 1990-11)

      A

      1530

      Mainly active load breaking capacity

      A

      630

      Cable charging current

      A

      630

      Power frequency withstand voltage 50Hz 1 min,:

       

       

      - To earth and between poles

      kV

      42

      - Across isolating distance

      kV

      45

      Impulse withstand voltage 1.2/50μ s:

       

       

      - To earth and between poles

      kV

      75

      - Across isolating distance

      kV

      85

      Mechanism Endurance

      cycles

      1000


      Overall and installation dimensions