<noframes id="rtnld">
    <listing id="rtnld"></listing>

      <form id="rtnld"><nobr id="rtnld"></nobr></form>

      Hello! welcomeZhejiang Xikai Electric Co. , Ltd.
      Zhejiang Xikai Electric Co. , Ltd.
      Contact
      Zhejiang Xikai Electric Co. , Ltd.
      Mailbox:wzxikai@wzxikai.com
      Tel:+86 577 61666 016
      address:No.271, Weishiqi Road, Yueqing Economic Development Insuatrial Zone, Yueqing, Zhejiang.

      product list

      Indoor high voltage load switch
      14/5000 Indoor vacuum circuit breaker
      Outdoor vacuum circuit breaker
      Outdoor high voltage load switch
      Outdoor high voltage disconnector
      Outdoor drop fuse
      High voltage current limiting fuse series
      High voltage complete set
      current position:Home>Product Center

      Product Center

        • FZN25-12 Indoor Medium Voltage Vacuum Load Break Switch

        FZN25-12 Indoor Medium Voltage Vacuum Load Break Switch

        FZN25-12D/T630-20 Indoor AC medium voltage vacuum load break switch is three-phase AC 50/60 Hz, rated voltage 12kV indoor installation, which is suitable for using in industrial and mining situation and so on enterprise substation and transformer and cable charging current. It had manual and motor operating mechanism that is advantageous to realize remote control. FZRN25-12D/T[]-31.5 indoor AC medium voltage vacuum load break switch with fuse combination, The versions combined with HRC fuses are particularly suitable for the protection of distribution transformers up to 1250 kVA, to break fault current and over load current.


         Technical Information

        Technical Specification

         

         

        Rated voltage

        kV

        12

        Rated current

        A

        630

        Rated power frequency

        Hz

        50/60

        Short circuit making capacity

        kA Peak.

        50

        Peak withstand current

        kA Peak.

        50

        Short time current

        kA eff.

         

        1Sec.

         

        25

        3Sec.

         

        20

        Max. breaking capacity in co-operation with fuses IEC 62271-105(IEC 420 1990-11)

        A

        2000

        Max. fuse current(XRNT Fuse)

        A

        200

        Power frequency withstand voltage 50Hz 1 min,:

         

         

        - To earth and between poles

        kV

        42

        - Across isolating distance

        kV

        48

        Impulse withstand voltage 1.2/50μ s:

         

         

        - To earth and between poles

        kV

        75

        - Across isolating distance

        kV

        85

        Mechanism Endurance

         

         

        -Vauum interrupter

        cycles

        10000

        -Main switch and Earth Switch

        cycles

        2000


        Overall and installation dimensions