      Hello! welcomeZhejiang Xikai Electric Co. , Ltd.
      Zhejiang Xikai Electric Co. , Ltd.
      Contact
      Zhejiang Xikai Electric Co. , Ltd.
      Mailbox:wzxikai@wzxikai.com
      Tel:+86 577 61666 016
      address:No.271, Weishiqi Road, Yueqing Economic Development Insuatrial Zone, Yueqing, Zhejiang.

      product list

      Indoor high voltage load switch
      14/5000 Indoor vacuum circuit breaker
      Outdoor vacuum circuit breaker
      Outdoor high voltage load switch
      Outdoor high voltage disconnector
      Outdoor drop fuse
      High voltage current limiting fuse series
      High voltage complete set
      current position:Home>Product Center

      Product Center

        • LW36- 126 High Voltage Sulfur Hexafluoride Circuit Breaker

        LW36- 126 High Voltage Sulfur Hexafluoride Circuit Breaker

        LW36-126 HV Sulfur Hexafluoride Circuit Breaker is a three-pole AC 50Hz outdoor high-voltage switchgear. It is mainly used for the control and protection of 110 kV power system, and can also be used as a contact circuit breaker.

        Technical Information

        Technical Specification

         

         

         

         

         

         

         

        Rated voltage

         

        kV

         

         

        126

         

         

        Rated Frequency

         

        Hz

         

         

        50

         

         

        Rated current

         

        A

         

         

        3150

         

         

        Isc Isc rated short circuit breaking current

        kA

        40

        31.5

         

        40

         

        31.5

        Rated short circuit switching current (peak value)

        kA

        100

        80

         

        100

         

        80

        Rated short-term withstand current (RMS)

        kA

        40

        31.5

         

        40

         

        31.5

        Rated short circuit duration

        s

        4

        4

         

        4

         

        4

        Rated peak withstand current

        kA

        100

        80

         

        100

         

        80

        Rated line charging switching current

        A

         

         

        31.5

         

         

        Rated interrupting current of different phase grounding

        A

         

         

        ISC87%

         

         

        Fracture

        kV

        230+73

        230

         

        230

         

        230

        1min power frequency

        Interpolar/Ground-to-Ground

         

        230

        230

         

        230

         

        230

         

        Fracture

        kV

        550+103

        550

         

        550

         

        550

        Tolerance Voltage (RMS)

        Interpolar/Ground-to-Ground

         

        550

        550

         

        550

         

        550


        Overall and installation dimensions