        • FZW32 outdoor high voltage isolation vacuum load switch

        FZW32 outdoor high voltage isolation vacuum load switch

        FZW32 Outdoor Vacuum Load Break Switch is used for power system, it is suitable for 12kV 50Hz three-phase power system. The frame of this switch is applied with the stainless steel or steel with hot-dip galvanization and anti-UV coating. All the elements are used the stainless steel. To make sure the stable and perfect function of the switch.

        Technical Information

        Technical Specification

         

         

         

         

        Rated voltage

         

        kV

        12

        40.5

        Rated frequency

         

        Hz

        50

        50

        Rated current

         

        A

        630

        1250

        Rated active load breaking current

        A

        630

        1250

        Rated closed-loop breaking current

        A

        630

        1250

        5% rated active load breaking current

        A

        31.5

        62.5

        Rated cable charging breaking current

        A

        10

        25

        Rated no-load transformer breaking capacity

        kVA

        1600

        1600

        Rated breaking capacitor bank current

        A

        100

        100

        1min power frequency withstand voltage: vacuum fracture, phase, relative / isolation fracture

        kV

        42/48

        68/95/110

        Lightning impulse withstand voltage: phase-to-phase, relative/isolated fracture

        kV

        75/85

        185/215

        ated short-time withstand current (thermal stability)

        kA

        20

        25

        Rated short circuit duration

        S

        4

        4

        ated peak withstand current (dynamic stability)

        kA

        50

        63

        Rated short circuit closing current

        kA

        50

        63

        Mechanical life

         

        Times

        10000

        10000

        Vacuum arcing contacts allow wear thickness

        mm

        0.5

        0.6

        Manual operating torque

         

        N.m

        ≤200

        ≤300

         

         

        Contact opening distance

        mm

         

        5±1

         

         

        Average opening speed

        m/s

         

        1.1±0.2

         

         

        Three-phase opening

        ms

         

        ≤5

        Load switch vacuum interrupter assembly adjustment

         

        Three-phase closing

        ms

         

        ≤2

         

         

        Charged body and relative distance

        mm

         

        >200

         

         

        Auxiliary loop resistance

        μΩ

         

        ≤300


        Overall and installation dimensions