      • GW1-12 Outdoor High Voltage Ac Disconnector
      • GW1-12 Outdoor High Voltage Ac Disconnector
      • GW1-12 Outdoor High Voltage Ac Disconnector

      GW1-12 Outdoor High Voltage Ac Disconnector

      GW1-12 series outdoor high-voltage AC isolating switch (hereinafter referred to as “isolation switch”), suitable for installation on outdoor high-voltage power distribution equipment line, for 10kV line to be connected under voltage and no load, and for high voltage to be overhauled Electrical equipment such as busbars and circuit breakers can be electrically isolated from live high-voltage lines, and can also be used to separate small capacitive currents and inductor currents. The isolating switch is a double-column vertical open type with manual or electric mechanism for three-phase linkage. The isolating switch complies with GB 1985-2014 "High Voltage AC Isolation Switch and Grounding Switch", DL/T 486-2010 "High Voltage AC Isolation Switch and Grounding Switch" and other technical standards.

      Technical Information

      Technical Specification

       

       

       

       

       

       

       

       

       

       

       

      Rated voltage

       

      kV

       

       

       

      12

       

       

      24

      40.5

      Rated frequency

       

      Hz

       

       

       

       

       

      50

       

       

      Rated current

       

      A

       

      630

       

      1250(1600)

      630

      Rated short-time withstand current and duration

      Isolation switch

      kA/s

      20/4

       

      25/4

       

      25/4

       

      31.5/4

      20/4

      25/4

      Grounding switch

      kA/s

      20/2

       

      25/2

       

      25/2

       

      31.5/2

      20/2

      25/2

      Rated peak withstand current

      kA

      25

       

      63

       

      63

       

      80

      25

      63

      Rated short-time power frequency withstand voltage

      Interphase and ground (dry test)

      kV/min

       

       

       

      42/1

       

       

      50

      95

      Fracture (dry test)

      kV/min

       

       

       

      48/1

       

       

      60

      115

      Phase to ground (wet test)

      kV/min

       

       

       

      42/1

       

       

      50

      85

      Lightning impulse withstand voltage

      Phase to ground

      kV

       

       

       

      75

       

       

      125

      185

      Fracture

      kV

       

       

       

      85

       

       

      145

      215

      Loop resistance

       

      μΩ

      ≤100

       

      ≤80

      ≤90

      ≤100

           

       

      Mechanical life  
      Times
      Isolation switch / grounding switch 



      Overall and installation dimensions