<noframes id="rtnld">
    <listing id="rtnld"></listing>

      <form id="rtnld"><nobr id="rtnld"></nobr></form>

      Hello! welcomeZhejiang Xikai Electric Co. , Ltd.
      Zhejiang Xikai Electric Co. , Ltd.
      Contact
      Zhejiang Xikai Electric Co. , Ltd.
      Mailbox:wzxikai@wzxikai.com
      Tel:+86 577 61666 016
      address:No.271, Weishiqi Road, Yueqing Economic Development Insuatrial Zone, Yueqing, Zhejiang.

      product list

      Indoor high voltage load switch
      14/5000 Indoor vacuum circuit breaker
      Outdoor vacuum circuit breaker
      Outdoor high voltage load switch
      Outdoor high voltage disconnector
      Outdoor drop fuse
      High voltage current limiting fuse series
      High voltage complete set
      current position:Home>Product Center

      Product Center

        • GW5-40.5W Outdoor High Voltage Ac Disconnector

        GW5-40.5W Outdoor High Voltage Ac Disconnector

        GW5-40.5 series outdoor high-voltage AC isolating switch (hereinafter referred to as “isolation switch”) is an outdoor high-voltage electrical equipment with a frequency of 50Hz. It is used for the connection of high-voltage lines under voltage and no load, and for the high-voltage busbars being repaired. Electrical equipment such as circuit breakers can be electrically isolated from live high-voltage lines. It can also be used to separate small capacitive currents and inductor currents. The isolating switch complies with GB 1985-2014 "High Voltage AC Isolation Switch and Grounding Switch", DL/T 486-2010 "High Voltage AC Isolation Switch and Grounding Switch" and other technical standards

        Technical Information

        Technical Specification

         

         

         

         

         

         

         

        Rated voltage

        kV

         

        40.5

         

         

        Rated frequency

        H

         

        50

         

         

        Rated current

        A

        630

         

        1250

         

        2000

        Rated short-time withstand current

        kA

        20/25

         

        25/31.5

         

        31.5

        Rated short-time withstand current (peak)

        kA

        50/63

         

        63/80

         

        80

        Rated short-time power frequency withstand voltage

        kV/min

        95/1nterphase, earth, dry test

        118/1nterphase, earth, dry test

        95/1nterphase, ground, and wet test

        Rated lightning impulse withstand voltage

        kV

        185/1 earth

        215 Fracture

        Rated short-time withstand current duration

        S

        4 Isolation switch、

        2Grounding switch

        Creepage distance

        mm

        ≥1256Class e antifouling

         

        Main loop resistance

        μΩ

        ≤100

         

         

         

        ≤80

         

        Operating mechanism

        Human operating agency

         

        CS17-G5 Without grounding switch

         

        Main knife Cs17-G5, ground knife Cs17-G2 (with single/double earthing switch)

        Motor operating mechanism

         

        CJ6 type, motor voltage AC380V or DC220V, control voltageAC220V or DC220V, auxiliary contact 8 normally open 8 nor mally closed (standard)

        Mechanical life

        Times

         

        Isolation switch grounding switch


        Overall and installation dimensions