        • Air insulated switchgear (Ring Main Units)

        Air insulated switchgear (Ring Main Units)

        XGN15 SF6 Insulated Ring Main Units is either compact or extensible metal enclosed switchgear, which takes SF6 Load Break Switch as main switch and whole cell insulated by air, it is suitable for distribution automation, with characteristics of simple structure, easy operation, reliable interlock and easy installation. The switchgear can be supplied satisfied technical program direct at different service condition and different uses' requirement. Adopting of sensor technology and newest relay protection, with the addition of advanced technical characteristics and easy erection scheme, it is completely meet the requirements of ever-changing market. XGN15 SF6 Insulated Ring Main Units takes FL( R)N36 or FL( R)N48 SF6 Load Break Switch made by Xikai as main switch, also can be installed with VS1 VCB with international highest technical level, or VSG according the requirements of users. The operation of main switch is manual or motorized, to be coupled with FTU or RTC, can meet the requirements of remote control, distant signal, remote inspection.

        Technical Information

        Technical Specification

         

         

         

         

         

        Item

         

        Unit

        Load Break Switch Unit

         

        LBS-Fuse Combination Unit

        Vacuum Circuit Breaker Unit

        Rated Voltage

         

        kV

        12/24

         

        12/24

        12/24

        Rated Power Frequency

         

        Hz

        50/60

         

         

         

        Rated Current

        Main Busbar

        A

        630

         

         

         

        Branch Busbar

         

        630

         

        (depend on rated current of fuse)

        630

        Power Frequency

         

        To Earth And Between Poles

        kV

         

        42/55

         

        Withstand Voltage 50hz 1min

         

        Across Isolating Distance

        kV

         

        48/70

         

        Impulse Withstand Voltage1.2/50μs

         

        To Earth And Between Poles

        kV

         

        75/125

         

         

         

        across Isolating Distance

        kV

         

        85/145

         

         

         

         

        Main Circle

        kA

        20/3s

         

        -

        25/2s

        Short Time Withstand Current

         

         

        Earthing Circle

        kA

        20/2s

         

        -

        25/2s

        Rated Peak Withstand Current

        kA

        62.5/50

         

        -

        63/50

        Rated Short-circuit Breaking Capacity

        kA

         

        67/50

         

        rated Transfer Current

         

        A

        -

         

        1700

        -

        Rated On Load Breaking Current

        A

        630

         

        -

        -

        rated Close Loop Breaking Current

        A

        630

         

        -

        630

        rated Cable Charging Current

        A

        10

         

        -

        15

        Protection Level

         

         

         

         

        IP3X

         

        Mechanism Endurance

         

         

        LBS

        cycles

        5000

         

        5000

        10000

         

         

         

        ES

        cycles

        2000

         

        2000

        2000


        Overall and installation dimensions

        ?